Campervan Cable Sizing & Voltage Drop Calculator
Calculate the copper cable size required to meet your chosen voltage-drop target, compare standard cable sizes and estimate the power lost along your campervan’s DC wiring.
Designed for 12V, 24V and 48V campervan electrical systems.
Calculate Your Cable Size
Enter your electrical system details below. The calculator uses the total positive and negative copper cable length to estimate voltage drop.
Please enter valid positive values for current and length.
Your Cable Calculation
These calculations estimate voltage drop only. They do not verify cable ampacity, fuse size, short-circuit protection or installation safety.
Compare Standard Cable Sizes
See how increasing conductor size reduces estimated voltage drop and resistive power loss.
| Cable Size | Voltage Drop | Drop % | Power Loss |
|---|---|---|---|
| Enter your values and calculate. | |||
Green highlighting indicates the first listed cable size meeting your chosen voltage-drop target. It does not establish safe current capacity.
How Does This Cable Calculator Work?
The calculator estimates conductor resistance using the cross-sectional area of copper cable, its length and its temperature.
Calculation Formula
Resistance:
R = ρ × L ÷ A
Voltage drop:
Vdrop = I × R
Power loss:
Ploss = I² × R
Where:
- R = cable resistance in ohms
- ρ = copper resistivity in Ω·mm²/m
- L = total conductor length in metres
- A = conductor cross-section in mm²
- I = current in amps
At 20°C, the calculator uses a nominal copper resistivity of 0.0175 Ω·mm²/m and a temperature coefficient of 0.00393 per °C.
For chassis-return circuits or different positive and negative conductor sizes, the actual return-path resistance must be calculated separately. This calculator assumes two equal-length copper conductors of the same cross-sectional area.
What Is an Acceptable Voltage Drop?
A 2.5% target is a useful starting point for many DC cable calculations, but the acceptable value depends on the circuit.
1% Drop
A more demanding design target that may require larger conductors.
2.5% Drop
A general target consistent with Victron Energy’s published DC wiring guidance.
3–5% Drop
May be considered for some circuits, but could be unsuitable for sensitive equipment or chargers.
Charging equipment, inverters and sensitive electronics may have specific voltage requirements. Always follow the equipment manufacturer’s instructions.
How Do You Choose the Correct Fuse?
Cable sizing and fuse selection are related but separate tasks.
A suitable protective device must be coordinated with the cable’s current-carrying capacity, normal load, maximum DC voltage and prospective short-circuit current.
It must also have appropriate operating characteristics and interrupting capacity.
More CamperVoltHub Planning Tools
Frequently Asked Questions
What cable size do I need for a 12V campervan?
It depends on current, cable length, voltage drop, installation conditions and manufacturer specifications. Enter your circuit details above to estimate the voltage-drop requirement, then separately verify the cable’s current-carrying capacity.
Does cable length affect voltage drop?
Yes. For the same conductor size and current, a longer cable has more resistance and produces greater voltage drop.
Can I use this calculator for DC-DC chargers?
You can use it to estimate copper conductor voltage drop, provided you enter the correct current for the specific input or output circuit. A charger’s vehicle-side input current may differ from its leisure-battery output current. Follow the charger’s installation instructions.
Can I use this calculator for 230V mains wiring?
No. This calculator is intended for low-voltage DC copper circuits. It does not design or verify 230V AC installations.
Does this calculator recommend fuse sizes?
No. Fuse selection requires additional information about cable ampacity, fault current, protective-device ratings and equipment specifications.